Fire-Resistant Glass
Integrity and insulating fire glass supplied and fitted into tested frames.
Learn more →
Fire-rated glazing is glass that has been tested, together with its frame, beads and seals, to hold back fire for a set time. We survey, supply and install fire-resistant glass, glazed screens, doors and vision panels across the UK, and hand over the evidence that proves what was fitted.
Tell us what you need. We reply with next steps and a guide price.
The rating belongs to the whole system, not the glass alone. A fire-resistant pane in the wrong frame, with the wrong beads or missing seals, will not perform as tested. That is why every job starts with the evidence.
We fit glass, frames, beads and seals as one tested or assessed system, within its stated pane sizes.
We record what is installed and flag what cannot be proven, rather than guessing a rating.
Integrity where it is allowed, insulation where people need protecting — the choice that sets most of the cost.
Classification references, glass marks and installation photographs for your fire safety records.
Fire-resistance classes come from BS EN 13501-2. The letters say what the glazing stops; the number is the tested time in minutes.
Stops flames and hot gases passing. Heat still comes through, so its use on escape routes is limited.
Integrity fire glass →Also caps radiated heat at 15 kW/m², one metre from the glass. Reduces the risk to people and materials nearby.
How EW differs →Limits the temperature rise on the protected face, so people can pass more safely. Far fewer restrictions on where it can be used.
Insulated fire glass →Every service is supplied and installed, or surveyed, by specialists working to the manufacturer's tested details.

Integrity and insulating fire glass supplied and fitted into tested frames.
Learn more →
EI 30 to EI 120 glass that blocks heat as well as flames.
Learn more →
E and EW glass where flames and hot gases must be stopped.
Learn more →
Cracked or broken fire glass replaced to the original specification.
Learn more →
Replace old Georgian wired glass with modern fire glass.
Learn more →
Internal glazed screens that keep compartments and corridors protected.
Learn more →
Slim steel frames for long spans, high ratings and heavy glass.
Learn more →
Light, modern aluminium framing tested for fire.
Learn more →
Hardwood screens and borrowed lights tested for fire.
Learn more →
Office glass partitions where the wall has to be fire-resisting.
Learn more →
Butt-jointed fire glass walls with minimal frames.
Learn more →
Glazed screens and doors on protected stairs, lobbies and corridors.
Learn more →
Doorsets with large glazed panels, tested as complete units.
Learn more →
Replacement and new vision panels fitted to the door's evidence.
Learn more →
Glazed over-panels, side lights and borrowed lights around fire doors.
Learn more →
Facade glazing tested for fire where boundaries or compartments demand it.
Learn more →
Windows near boundaries and protected routes, tested for fire.
Learn more →

Surveys that identify what fire glazing you have and what needs fixing.
Learn more →
Putting right the defects found in surveys and fire risk assessments.
Learn more →We publish genuine, verifiable reviews from completed jobs. As projects complete, independent reviews will appear here.
No invented testimonials. Until verified reviews are live, judge us on the detail: every quote names the tested system, its classification and the evidence it relies on, so you can check the proposal line by line.
Send sizes, the rating required, photos of glass marks or your inspection report.
We measure, record existing marks and check frames, substrates and fire-stopping.
Your quote names the tested system, classification and evidence it relies on.
Installed to the system details, then a handover pack with photographs and references.
Yes. We arrange surveys and installation across England, Wales, Scotland and Northern Ireland, and design to the building rules of the nation the building is in.
Work is carried out by specialist fire glazing installers working under S&K Property Investments and Improvement Ltd, which contracts with you and is responsible for the work.
We do not claim scheme membership on this site. We install tested systems to the manufacturer's evidence and hand over the evidence references so building control and your fire risk assessor can check them. If your project requires a certificated installer, tell us at quote stage.
Initial site surveys for quoted installation work are free and without obligation. Standalone condition surveys with a written report are chargeable; see our prices page.
A schedule of the glazed elements installed or repaired, the classifications, glass marks, evidence references and photographs of seals and fixings before they were closed up.
Small repairs depend mainly on glass availability; integrity glass is usually quicker to supply than insulating glass. Made-to-measure screens depend on drawings, approvals and fabrication.
We design to the rules of the nation the building is in. Choose your area for local coverage and services.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.